The algorithm of repair work for electricity pilons of transmission line

Abstract

The algorithm of repair work for electricity pilons of transmission line

Egorochkina I.O., Shlyahova E.A., Cherakov A.V., Manvelyan L.A., Kucherenko D.Yu.

Incoming article date: 09.12.2016

The article presents the algorithm of repair work for electricity pilons of transmission line.The technical diagnostics based on complex method includes a visual inspection, instrumental and vibration diagnostics for electricity pilons of transmission lines. Pilons has defects: inclined cracked faces with a length of 25-30 cm , with a crack width of 0,4-0,7 mm . Were selected effective repair compositions for restoring reinforced concrete structures rack transmission towers:modified fine-grained concrete, polymer concrete. The article presents an example of analytical modeling of natural vibrations of a reinforced concrete pilons of transmission lines with defects in the base. This article contains a list of repair works. The material presented can be used in the development of methods of diagnostics and monitoring of technical condition of different structures of the core type.

Keywords: Algorithm, repair, category of defects, non-destructive testing methods, pilons of transmission lines, vibrodiagnostics